Compliance with communications, medical safety certification
2 MOPP isolation protection
Leakage current ≤ 100μA
Level 6 energy efficiency
Standby power consumption ≤0.075W
5V-48V output, up to 36W
Working sea dial height 5000 meters
Input Characteristics
Input voltage 80-264VAC
Frequency range 47-63 Hz
Input current 1.0a at 80VAC input
Surge current 70A Max at 240VAC input and cold start conditions
Contact current ≤100 μa at 264VAC input
The environment in general
Working temperature of 0 ~ 45 ℃ overall dimensions (length) 103.7 x57.5 (wide) x30.0 (high) mm
Storage temperature - 20 ~ 60 ℃ weight 210 grams
Working humidity 10 ~ 90% RH, no condensation MTBF & gt; 100,000 hours MIL-HDBK-217 at 25 ° C ambient temperature.
Store humidity 5 ~ 90% RH insulation impedance withstand voltage 4000 v
The working altitude is 5000m
Safety Approval
Security Agency/Mark Medical (Meet) I.T.E
CB IEC60601-1 / IEC60601-1-11 IEC62368
UL ANSI / AAMI ES60601-1 / 60601-1-11 UL62368
CAN / CSA-C22.2 NO。60601-1
TüV SUD/Mark EN60601-1 / EN60601-1-11 -
TüV SUD/GS - EN62368
CE - EN62368
CCC - GB4943
PSE - J62368
KC - K60950-1
RCM - AS/NES62368
Models & Parameters
Model | voltage | electric current | Rated power | Ripple and noise | Voltage tolerance | Linearity and load | Average efficiency | Start delay time |
(V) | (A) | (maximum) | Adjustment rate | |||||
UES36C1-XXXYYYSPA | 5.0 | 0.01-6.00 | 30.0W | 200mVpk-pk | ±5% | Linear adjustment rate: ±1% Load adjustment rate: ±5% | 85.00% | ≤3s |
5.1-5.9 | 0.01-5.00 | 30.0W | 200mVpk-pk | ±5% | 88.30% | ≤3s | ||
7.5-14.0 | 0.01-4.00 | 36.0W | 200mVpk-pk | ±5% | 88.30% | ≤3s | ||
14.1-21.0 | 0.01-2.40 | 36.0W | 200mVpk-pk | ±5% | 88.30% | ≤3s | ||
21.1-30.0 | 0.01-1.63 | 36.0W | 200mVpk-pk | ±5% | 88.30% | ≤3s | ||
30.1-48.0 | 0.01-1.16 | 36.0W | 300mVpk-pk | ±5% | 88.30% | ≤3s |