Product features
The product features
Compliance with communications, medical safety certification
2 MOPP isolation protection
Leakage current ≤ 10μA
Level 6 energy efficiency
Standby power consumption ≤0.075W
4.2V-12V output, up to 6W
Working sea dial height 5000 meters
With a variety of interchangeable AC pins
Input Characteristics
Input voltage 80-264VAC
Frequency range 47-63 Hz
Input current 0.2A, 90VAC input condition
Surge current 30A Max at 240VAC input and cold start conditions
Contact current ≤10 μa at 264VAC input
The environment in general
Working temperature of 0 ~ 45 ℃ overall dimensions (length) 74.0 x43.0 (wide) x33.0 (high) mm
Storage temperature - 20 ~ 60 ℃ weight 85 grams
Working humidity 10 ~ 90% RH, no condensation MTBF & gt; 100,000 hours MIL-HDBK-217 at 25 ° C ambient temperature.
Storage humidity 5-90% RH
The working altitude is 5000m
Safety Approval
Safety/organization Medical I.T.E
CB IEC60601-1 / IEC60601-1-11 IEC62368-1
ULANSI / AAMI ES60601-1 / 60601-1-11 -UL62368-1
CAN / CSA-C22.2 NO。60601-1
TUV-Mark EN60601-1 / EN60601-1-11 -
TüV Rheinland-GS - EN62368-1
CE - EN62368
CCC - GB4943.1
PSE - J62368
KC - K60950-1
RCM - AS / NES62368
Models & Parameters
Model | voltage | electric current | Rated power | Ripple and noise | Voltage tolerance | Linearity and load | Average efficiency | Start delay time |
(V) | (A) | (maximun) | Adjustment rate | |||||
UES06WNCP1-XXXYYYSPA | 4.2 | 0.01-1.20 | 5.04W | 200mVpk-pk | ±5% | Linear adjustment rate: ± 1% Load adjustment rate: ± 5% | 73.83% | ≤3s |
5.0-6.0 | 0.01-1.00 | 6.00W | 150mVpk-pk | ±5% | 73.77% | ≤3s | ||
6.1-7.0 | 0.01-0.86 | 6.00W | 150mVpk-pk | ±5% | 78.16% | ≤3s | ||
7.1-8.0 | 0.01-0.75 | 6.00W | 200mVpk-pk | ±5% | 78.26% | ≤3s | ||
8.1-8.9 | 0.01-0.67 | 6.00W | 200mVpk-pk | ±5% | 78.38% | ≤3s | ||
9.0-10.0 | 0.01-0.60 | 6.00W | 200mVpk-pk | ±5% | 78.35% | ≤3s | ||
10.1-11.0 | 0.01-0.54 | 6.00W | 200mVpk-pk | ±5% | 78.42% | ≤3s | ||
11.1-12.0 | 0.01-0.50 | 6.00W | 200mVpk-pk | ±5% | 78.53% | ≤3s |