Product features
Product features
Meet the communication, medical safety certification
2 MOPP isolation protection
PF> 0.95 @ 230 vac full load
Leakage current ≤ 100μA
Working sea dial height 5000 meters
Input Characteristics
Input voltage 80-264VAC
The frequency range is 47-63Hz
Input current: 3.0A at 80VAC input
Surge current 120A Max at 240VAC input and cold start conditions
Contact current ≤ 100 μa at 264VAC input
The environment in general
Working temperature of -10 ~ 40 ℃ dimension (long) 165x69.5 (wide) x24.25 (high) mm
Storage temperature - 20 ~ 60 ℃ in weight 800 g
Working humidity 10 ~ 90% RH, noncondensable MTBF & gt; 100,000 HRS MIL-HDBK-217 at 25 ° C ambient temperature.
Storage humidity 5 ~ 90% RH isolation compression strength 5656 VDC input to the output
The working altitude is 5000m
Safety Approval
Security Agency/Mark Medical I.T.E
CB IEC60601-1/IEC60601-1-11 IEC62368-1
UL ANSI/AAMI ES60601-1/60601-1-11 UL62368-1
CAN/CSA-C22.2 NO. 60601-1
TUV-SUD/Mark EN60601-1/EN60601-1-11 -
TUV-SUD/GS - EN62368-1
CE - EN62368
Models & Parameters
Model | voltage | electric current | Rated power | Ripple and noise | Voltage tolerance | Linearity and load | Average efficiency | Start delay time |
(V) | (A) | (maximun) | Adjustment rate | |||||
UES180D"Z"-XXXYYYSPA | 11.0-12.0 | 0.01-12.5 | 150W | 150mVpk-pk | ±5% | Linear adjustment rate: ±1% | 92.00% | ≤3s |
12.1-13.0 | 0.01-11.5 | 150W | 150mVpk-pk | ±5% | 92.00% | ≤3s | ||
13.1-14.0 | 0.01-10.7 | 150W | 150mVpk-pk | ±5% | 92.00% | ≤3s | ||
14.1-15.0 | 0.01-10.0 | 150W | 150mVpk-pk | ±5% | 92.00% | ≤3s | ||
17.1-18.0 | 0.01-10.0 | 180W | 180mVpk-pk | ±5% | 93.00% | ≤3s | ||
18.1-19.0 | 0.01-9.47 | 180W | 190mVpk-pk | ±5% | 93.00% | ≤3s | ||
19.1-20.0 | 0.01-9.00 | 180W | 200mVpk-pk | ±5% | 93.00% | ≤3s | ||
20.1-21.0 | 0.01-8.57 | 180W | 210mVpk-pk | ±5% | 93.00% | ≤3s | ||
21.1-22.0 | 0.01-8.18 | 180W | 220mVpk-pk | ±5% | 93.00% | ≤3s | ||
22.1-23.0 | 0.01-7.82 | 180W | 230mVpk-pk | ±5% | 93.00% | ≤3s | ||
23.1-24.0 | 0.01-7.50 | 180W | 240mVpk-pk | ±5% | 93.00% | ≤3s | ||
24.1-25.0 | 0.01-7.20 | 180W | 250mVpk-pk | ±5% | 93.00% | ≤3s | ||
25.1-26.0 | 0.01-6.92 | 180W | 260mVpk-pk | ±5% | 93.00% | ≤3s | ||
26.1-27.0 | 0.01-6.66 | 180W | 270mVpk-pk | ±5% | 93.00% | ≤3s | ||
35.1-36.0 | 0.01-5.00 | 180W | 300mVpk-pk | ±5% | 94.00% | ≤3s | ||
36.1-37.0 | 0.01-4.86 | 180W | 300mVpk-pk | ±5% | 94.00% | ≤3s | ||
37.1-38.0 | 0.01-4.73 | 180W | 300mVpk-pk | ±5% | 94.00% | ≤3s | ||
38.1-39.0 | 0.01-4.61 | 180W | 300mVpk-pk | ±5% | 94.00% | ≤3s | ||
39.1-40.0 | 0.01-4.50 | 180W | 300mVpk-pk | ±5% | 94.00% | ≤3s | ||
47.1-48.0 | 0.01-3.75 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
48.1-49.0 | 0.01-3.67 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
49.1-50.0 | 0.01-3.60 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
50.1-51.0 | 0.01-3.52 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
51.1-52.0 | 0.01-3.46 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
52.1-53.0 | 0.01-3.39 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s | ||
53.1-54.0 | 0.01-3.33 | 180W | 400mVpk-pk | ±5% | 94.00% | ≤3s |