Product features
Product features
Comply with communication, medical safety certification
2 MOPP isolation protection
DOE Efficiercy Level VI
CoC V5 Tier2(2016)
Contact current ≤ 100μA
Standby power consumption ≤0.075W
Working sea dial height 5000 meters
Input Characteristics
Input voltage 80-264VAC
The frequency range is 47-63Hz
Input current 0.8A at 80VAC input condition
Contact current ≤ 100 μa at 264VAC input
The environment in general
Working temperature of 0 ~ 45 ℃ overall dimensions (length) 88.5 x30.5 (wide) x48.8 (high) mm
Storage temperature - 20 ~ 60 ℃ in weight 128 g
Working humidity 10 ~ 90% RH, noncondensable MTBF & gt; 100000HRS MIL-HDBK-217 at 25℃ ambient temperature.
Storage humidity 5 ~ 90% RH isolation compression strength 5656 VDC input to the output
The working altitude is 5000m
Safety Approval |
Security Agency/Mark Medical I.T.E |
CB IEC60601-1 - |
CCC - GB4943.1 |
TuV Rheinland/Mark EN60601-1 - |
UL ANSI/AAMI ES 60601-1 - |
CAN/CSAC22.2NO.60601-1 |
Models & Parameters
Model | voltage | electric current | Rated power | Ripple and noise | Voltage tolerance | Linearity and load | Average efficiency | Start delay time |
(V) | (A) | (maximun) | Adjustment rate | |||||
UES24LZ1-120200SPA | 12.0 | 0.01-2.0 | 24W | 150mVpk-pk | ±5% | Linear adjustment rate: ±1% Load adjustment rate: ±5% | 86.8% | ≤3s |
landline