Product features
Load regulation rate product characteristics
Conform to communication and medical safety certification
2 MOPP isolation protection
Leakage current ≤ 100 μ A
Comply with class V energy efficiency
Standby power consumption ≤ 0.3w
Peak load: 200% rated load @230vac
Working altitude 5000 meters
The peak load can reach 7a and last for more than 1s
Input Characteristics
Input voltage 90-264VAC
Frequency range 47-63Hz
Input current 1.5A, under 90vac input condition
Environment commonly
Working temperature of 0 ~ 40 ℃ dimension 134 long) x64 (wide) x32 (high) mm
Storage temperature - 20 ~ 70 ℃ 125 g in weight
Working humidity 10 ~ 90% RH, noncondensable MTBF & gt; 100,000 HRS MIL-HDBK-217 at 25 ° C ambient temperature.
Storage humidity 5-95% RH
The working altitude is 5000m
Safety Approval |
Safety organization/sign medical communication (meet) |
CB IEC60601-1 IEC62368-1 |
Models & Parameters
Model | Voltag(V) | electric current (A) | power (W) | Ripple (maximum) mVpk-pk | Voltage tolerance | Linear and negative adjustment rates | Average efficiency | Start delay time |
UE63-XXXYYYSPA-OP | 18.0 | 0.01-3.50 | 63W | 240 | ±5% | Linear adjustment rate: ±1% Load adjustment rate: ±5% | 87% |
≤3s |